180° peel force tester / 180° peel force tensile tester

Double-sided tape peeling force testing machine of the release film release force can be used for the peel strength testing of adhesives, adhesive tapes, medical patches, self-adhesives, release papers, composite films, protective films and other products, as well as artificial leather, paper, Breaking and peeling properties of films and other products.

180° peel force tester / 180° peel force tensile tester

1.introductions

The Double-sided tape peeling force testing machine of the release film release force can be used for the peel strength testing of adhesives, adhesive tapes, medical patches, self-adhesives, release papers, composite films, protective films and other products, as well as artificial leather, paper, Breaking and peeling properties of films and other products. The release film release force peel strength testing machine uses a computer and an interface board to collect, save, process and print the test results, and can calculate the maximum force, yield force, average peel force, maximum deformation, yield point, elastic modulus and other parameters ; Can perform curve processing and support multiple sensors. The release film peeling strength tester is suitable for tapes, ceramics, automobiles, construction, composite materials, metals, food and medical equipment, packaging, paper, textiles, wood, rubber, communications and various special-shaped materials.

2. relative test method for Double-sided tape peeling force testing machine

GB/T 2790 adhesive 180 degree peel strength test method for a flexible-to-rigid test specimen assembly

ISO 8510-2 adhesive – peel test for a flexible-bonded-to-rigid test assembly – part 2: 180 degree peel

ISO 8510-1 adhesives – peel test for a flexible-bonded-to-rigid test specimen assembly – part 1: 90 degree peel

ISO 527-1 plastics – determination of tensile properties – part 1: general principles

GB/T 2791 adhesive – T peel strength test for a flexible-to-flexible test specimen assembly

GB/T 2792 measurement of peel adhesion properties for adhesive tapes

ISO 29862 self-adhesive tapes – determination of peel adhesion properties

GB/T 4851 test method for holding power of pressure sensitive adhesive tapes

GB/T 7754 test method for shear strength of pressure sensitive adhesive tapes (adhesive layer to back side of the tape)

GB/T 8808 test method for peel force of flexible laminated plastics

GB 13022 plastics – determination of tensile properties of films

ISO 1184 plastics – determination of tensile properties of films

GB/T 7753 test method for tensile properties of pressure sensitive adhesive tapes

3. Relative manufacturing and calibrating test method for Double-sided tape peeling force testing machine

GB/T2611 general requirements for testing machines

GB/T16491 electronic universal testing machine

GB/T16825.1 verification of static uniaxial testing machines --- part 1: tension / compression testing machines --- verification and calibration of the force measuring system

ISO7500-1 metallic materials--- verification of static uniaxial testing machine --- part 1: tension / compression testing machines --- verification and calibration of the force measuring system

ASTM E4 standard practice for force verification of testing machines

EN 10002-2 tensile testing of metallic materials --- part 2: verification of the force measuring system of the tensile testing machine

4. specifications of Double-sided tape peeling force testing machine

No

Item

Specification

1

Force capacity

100N,200N,500N,1000N,2000N,5000N

2

Force measuring range

0.4%-100%FS

3

Error of force value

Less than ±1% of set value

4

Resolution of test force

1/500000

5

Displacement resolution

0.0025mm

6

Accuracy of elongation measuring

±0.5%

7

Crossbeam speed range

0.05-500mm/min

8

Precision of displacement speed control

±1%(0.01-10mm/min); ±0.5%(10-500mm/min)

9

Accuracy of constant force, constant displacement, displacement   elongation control

When set value is less than 10%FS,error is less than ±1.0% of set value

When set value is more than 10%FS,error is less than ±0.1% of set value

10

Accuracy of deformation control

When set value is less than 0.05%FS,error is less than ±2.0%   of set value

When set value is more than 0.05%FS,error is less than ±0.5%   of set value

11

Distance between tensile grips

650mm

12

Voltage

Single phase,220V±10%,50Hz

13

Dimension

520x480x1550mm

14

Weight

80kg