It meets the requirements of GB/T16584 "Rubber - Determination of vulcanization characteristics by rotorless vulcanization instrument", ISO6502 requirements and T10, T30, T50, T60, T90 data required by Italian standards. This machine is used to determine the characteristics of unvulcanized rubber and find the most suitable curing time for the compound.

Rubber rotorless vulcanizer

Introduction
It meets the requirements of GB/T16584 "Rubber - Determination of vulcanization characteristics by rotorless vulcanization instrument", ISO6502 requirements and T10, T30, T50, T60, T90 data required by Italian standards. This machine is used to determine the characteristics of unvulcanized rubber and find the most suitable curing time for the compound. The machine adopts imported intelligent digital temperature control instrument, which is easy to adjust and set, wide temperature control range and high control precision. Its stability, reproducibility and accuracy are better than those of general rotary vulcanizer. The use of computer control and interface boards for data acquisition, storage, processing and printing of test results, making the function more powerful. It fully demonstrates its highly automated features. Also has curve comparison, amplification and other functions

Main Specifications
A. High precision sensor: 0~20N.m.
    Resolution: 0.001 N.m.
B. Control system: computer control and interface board for data acquisition, storage, processing and printing test results and curve processing.
C. Rotating system: Stepping Electronics speed motor + amplitude adjuster. Swing angle: ±0.5o ±1o.
D. Temperature control system: Using Inteligent digital temperature control instrument, real-time Automatism adjusts PID control parameters.
   Temperature control range 0--200°C, temperature control accuracy ≤±0.3°C, temperature resolution 0.1°C.
E. Data transmission method: RS232 transmission
F. Display mode: Vulcanize-105+WIN-XP test software computer screen display, plus excellent user software and advanced hardware equipment make the whole measurement very convenient, fast, accurate and enjoyable.
G. Cavity: Cr6wv material, in line with GB/T16584-1996 standard requirements.
F. Measurement and control method: humanized measurement and control method, mouse click-to-use or host panel touch button

Vulcanization test machine parameters
A. Temperature range: 0°C-200°C
B. Temperature measurement accuracy: ≤ ±0.3°C
C. Temperature control accuracy: ≤ ±0.3 °C
D. Temperature resolution: 0.1 ° C
E. Torque range: 0-10N.m 0-20N.m
F. Torque resolution: 0.001N.m
G. Cavity frequency: 1.7Hz
H. Amplitude: ±0.5o±1o
I. Ambient temperature: 0-35 ° C Relative humidity
J. Size: 540*660*1100mm
K. Quality: 150kg Power: 1kw